Stainless-lined washroom interior inside a sanitary module
03 / 10

Solutions · family

Sanitary & Septic

Wet rooms, laundries and tanks built in stainless steel, to camp-grade specification.

  • AISI 304 throughout
  • anti-Legionella mandatory
  • 6.5 / 7.0 m³ tanks
  • 12 air changes / hour
  • ISO 9001
  • ISO 14001
  • EN ISO 3834-2
  • EN 1090-1 EXC2
  • AQAP 2110
  • CSC approval
  • Defence trade licence
  • Registered defence supplier, CAGE code held

The hardest container Tanax builds, because it is the one that gets used every day by tired people and has to survive it. Stainless walls, stainless floor with a fall to the drain, water heaters with Legionella protection, ventilation sized for the occupancy, and lighting that meets a working standard. Plus the tanks that feed and empty it.

Specification

Shell

Type
ISO 1C, 6,058 × 2,438 × 2,591 mm, CSC certified
Tare, sanitary
max 6,500 kg
Tare, laundry
max 7,500 kg

Envelope

Insulation
PIR 100 mm plus vapour barrier, U ≤ 0.20 W/m²K
Wall and ceiling lining
AISI 304 stainless, 1.5 mm
Floor
AISI 304 stainless, 3 mm, diamond pattern, 1° fall to gully

Water

Sanitary heaters
10 L at the basins, 300 L for showers, both anti-Legionella
Laundry heaters
200 L class B IP-X5 plus 10 L, both anti-Legionella
Softening
mandatory on laundry, max 500 mg/l CaCO₃
Couplings
Storz 110-A / 75-C / 52-B adapter sets

Air

HVAC class
A++/A+, SEER ≥ 6.1, SCOP ≥ 4.0, R32
Air changes
min. 12 per hour

Light

Sanitary
300 lx normal, plus blackout 625-650 nm, auto, and 3 h emergency
Laundry
500 lx per EN 12464-1

Power

Sanitary supply
400/230 V 3-phase, 32 A IP-67 per EN 60309
Laundry supply
400/230 V 3-phase, 125 A IP-67
Supply cable
100 m sanitary, 30 m laundry

Tanks

Potable water
6.5 m³, stainless, ISO 1CX low frame, 0.812 m high
Wastewater
7.0 m³, stainless, gas-tight covers for H₂S / CH₄ / NH₃
Pumps
2 off, 5 m³/h, 6 bar, 8 m suction, 1.2 kW, IP-44, 55 dB(A)
Frost protection
automatic tank heating to −32 °C

How it is built

The decisions behind the numbers

Stainless is not a finish, it is the design.

1.5 mm AISI 304 on walls and ceiling, 3 mm on the floor with a diamond pattern and a one-degree fall to a floor gully. Around 60 m² of sheet per module. It costs more than a painted or GRP lining and it is the reason these units are still serviceable after a decade of daily use.

Legionella protection is mandatory on every heater.

Not an option, not a variant. Both the 10 litre point-of-use heater and the 300 litre shower heater carry it, and on the laundry unit the 200 litre machine heater carries it too. The laundry additionally gets water softening, because 500 mg/l of calcium carbonate destroys professional washing machines.

Sizing is done from occupancy, not from what fits.

A sanitary module is a WC section, two cubicles, two urinals, two basins, a 10 litre heater, a hose reel, and a shower section, three showers, two basins, two hand dryers, two folding seats, a 300 litre heater, a hose reel. A laundry serving six people at once needs six professional 8 kg washers and six 8 kg dryers stacked in pairs with the manufacturer's own stacking kit, not two industrial 20 kg machines. That distinction is worth about a quarter of the module price and it is the most common specification error in this category.

Tanks are stainless too, and they are the low-frame ISO 1CX.

0.812 m high, one third of an ISO 1C, so three stack into a single container slot for transport. Potable water at 6.5 m³, wastewater at 7.0 m³, both with two inspection openings, internal release mechanisms against entrapment, tank heating against freezing to −32 °C, and on the wastewater unit audible and visual high-level alarms.

Configurations

Variants and where to find them in the catalogue

  • WC cubicle inside a sanitary module

    Sanitary module, WC + shower sections

    • 20 ft
    • 2 WC, 2 urinals, 3 showers, 4 basins
    • 32 A
    View SKUs
  • Shower cubicles inside a sanitary module

    Sanitary variants, 5 / 10 / 20 ft

    • unisex, with WC, with separate WC, with corridor, with entryway
    View SKUs
  • Trough washbasin run in a washroom module

    Washroom unit

    • basins and mirrors only
    • with or without corridor
    View SKUs
  • Laundry module with stacked professional washers and dryers

    Laundry module

    • 6 × 8 kg washers + 6 × 8 kg dryers stacked
    • 125 A
    • softener
    View SKUs
  • Sanitary module exterior with the door open

    Site sanitary unit

    • 6,060 mm
    • construction-site grade
    View SKUs
  • Tank container on its platform, outdoors

    Sewage tank containers

    • 2,300 / 4,300 / 4,600 / 6,000 heated / 8,600 L
    View SKUs
  • Red technical container with a water tank, exterior

    Potable water container

    • 6.5 m³ stainless
    • ISO 1CX
    • 2 pumps
    • camlock 2 in
    View SKUs

Build detail

What the detail photography shows

  • Washbasin run and stainless splashback
    Washbasin run and stainless splashback
  • Water tank installation inside a module
    Water tank installation inside a module
  • Shower cubicle detail
    Shower cubicle detail
  • Open door of a red sanitary module showing the washroom
    Washroom seen from the entry door
  • Second view of a stainless-lined washroom interior
    Stainless lining, ceiling and wall junction
  • Laundry module interior with stacked machines and a service ladder
    Stacked machines and service access in a laundry module
  • Corridor sink inside a sanitary module
    Corridor basin at the module entry
  • Laundry module interior with washing machines in a fire-service unit
    Laundry module in service livery
  • Row of sinks inside a red sanitary container
    Basin row in a washroom module
  • Washing machine inside a sanitary module
    Washing machine bay

Visualisations

Renders and drawings, labelled as such

  • Cutaway visualisation of a sanitary module with basinsVisualisation
    VisualisationCutaway of a sanitary module
  • Interior visualisation of a modular sanitary containerVisualisation
    VisualisationSanitary module interior concept
  • Bathroom interior visualisation of a sanitary containerVisualisation
    VisualisationBathroom layout concept

Standards

What we build to and what we issue

  • EU 2184/2020
  • EN 14420-7
  • EN 60309
  • EN 12464-1:2021
  • Regulation (EU) 626/2011
  • EN 13501-1
StandardWhat it covers
EU 2184/2020Drinking water quality
EN 14420-7Camlock couplings
EN 60309Industrial plugs and sockets
EN 12464-1:2021Lighting levels by task
Regulation (EU) 626/2011HVAC energy labelling, SEER / SCOP
EN 13501-1Reaction to fire of the internal build-up

Documentation issued

Water system commissioning and disinfection record, Legionella protection confirmation, electrical inspection report, HVAC performance data, material certificates for stainless, CSC plate.

Proof

Deployments with a number in them

  1. 01

    6 module types, 1 livery

    A fleet of ISO modules for a national fire and rescue service: WC and shower blocks, laundry, material transport, septic, water and fuel tanks, plus platforms, all in a single livery and stackable three high.

    Read the case study
  2. 02

    40 sanitary modules

    28 men's and 12 women's, inside a single accommodation programme for a Central European ministry of defence.

    Read the case study
  3. 03

    58.5 m³ + 63 m³

    Potable water and wastewater designed as stackable low-frame tank containers for a deployable camp, so a full water system moves in nine and nine container slots.

    Read the case study

Scope

What the price includes, and what it does not

Included

  • Module and stainless lining
  • All sanitaryware
  • Water heaters with Legionella protection
  • HVAC
  • Lighting in all four modes
  • Internal plumbing and electrics to the module boundary
  • Hose reels and coupling adapter sets
  • Supply cable

Not included

  • External water supply
  • External drainage or connection to a sewer
  • Desludging
  • Consumables
  • Foundation or hard standing
If we have not built exactly this before, we will say so and tell you what we have built that is closest. Two prototype programmes in this factory were delivered below cost because nobody said that early enough. We do not do that any more, to you or to us.

Lead times

By variant

VariantLead time
Site sanitary unit5-7 weeks
Sanitary module, camp specification10-14 weeks
Laundry module12-16 weeks
Tank containers, potable or waste8-12 weeks

Engagement

Four ways to buy

01

Buy a catalogue unit

Pick from 94 published SKUs with full specifications, get a price, get a delivery date.

02

Modify a catalogue unit

Start from a standard shell and change what needs changing. Fastest route to a non-standard requirement.

03

Build to your specification

You bring the specification or the drawings, we review them, we build. Prototype and serial priced separately.

04

Subcontract fabrication

You are the prime, we are the hall. EN 1090-1 EXC2 capacity with AQAP 2110 assurance behind it.

Process

Specification to delivery in five steps

  1. 01

    Send the specification.

    A drawing, a tender annex, or three sentences. Whichever you have.

  2. 02

    Review, in writing.

    We tell you what is missing or contradictory before anyone quotes. 3-5 working days.

  3. 03

    Quotation.

    Bottom-up: material at purchase cost, co-operation, direct hours at a fully absorbed rate. 2-3 weeks for a complex build.

  4. 04

    Design freeze and build.

    Changes after freeze are variations, priced and agreed.

  5. 05

    Test, document, deliver.

    Factory acceptance where specified, full document pack, delivery and installation where quoted.

FAQ

Questions procurement asks

Why stainless and not GRP?

Because these get pressure-washed daily and hit with equipment. 1.5 mm AISI 304 on the walls and 3 mm on the floor is what survives it.

Do you supply the washing machines?

Yes, professional machines with the manufacturer's stacking kit. Six and six for a six-person self-service laundry.

Can the tanks be transported stacked?

Yes. The ISO 1CX frame is 0.812 m high, so three stack into one ISO 1C slot.

Is Legionella protection standard?

It is mandatory on every heater we fit, including the 10 litre point-of-use unit.

What supply do I need?

32 A three-phase for a sanitary module, 125 A for a laundry. Both IP-67 per EN 60309.

Send us the specification. A drawing, a tender annex, or three sentences.

You will get a written review of it inside a week, whether or not you buy anything.