20 ft Tank Container
20 ft ISO tank frame with a 24,000 litre barrel.
Last updated:

Tank and bulk

Photograph not uploaded yet
Photograph not uploaded yet
SKU: TC-TNK-20-ISO
On request
Pricing on request. Contact us for a tailored offer.
CSC certified
EU delivery
B2B invoice
Certification
- ISO 9001
- ISO 14001
- ISO 3834-2
- EN 1090-1
- CSC plate
Tanax Containers production is certified to the following standards. They cover the manufacturing, finishing and quality system behind every unit we supply, not the individual container.
Technical specifications
| Designation | TC-TNK-20-ISO | Manufacturer data sheet |
|---|---|---|
| Designation | ||
| ISO 668 designation | 1CC | ISO 668:2020 |
| External dimensions | ||
| External length | 6 058 mm | Manufacturer data sheet |
| External width | 2 438 mm | Manufacturer data sheet |
| External height | 2 591 mm | Manufacturer data sheet |
| Internal dimensions | ||
| Internal length | 5 898 mm | Manufacturer data sheet |
| Internal width | 2 350 mm | Manufacturer data sheet |
| Internal height | 2 350 mm | Manufacturer data sheet |
| Weights | ||
| Tare weight | 3 550 kg | Manufacturer data sheet |
| Max payload | 28 480 kg | Manufacturer data sheet |
| Max gross mass | 36 000 kg | Manufacturer data sheet |
| Capacity | ||
| Internal volume | 33.1 m³ | Manufacturer data sheet |
| Internal volume in cubic feet | 1168.9 ft3 | Manufacturer data sheet |
| Tank capacity | 24 000 l | Manufacturer data sheet |
| Construction | ||
| Construction material | Steel frame and barrel | Manufacturer data sheet |
| Fittings and finish | ||
| Paint finish | RAL 5010 (gentian blue) | Manufacturer data sheet |
Figures not published by the manufacturer: ISO 6346 size and type code, Door opening width, Door opening height, Floor construction, Roof configuration, Standard fittings
Specification notes
- Tare 3,550 kg plus payload 28,480 kg sums to 32,030 kg, 3,970 kg below the stated 36,000 kg max gross.
- Internal cube capacity is printed as 33.1 m3, which is the swept volume of the 20 ft frame, not the 24.0 m3 barrel capacity. The two figures describe different things.
- Design pressure, test pressure, permitted media class, T code and IMO type are not published. Without a design pressure the ISO 6346 T type code cannot be determined.
- Manhole and valve sizes, insulation and heating are not published.