OFFICE AND LIVING
Site offices, accommodation cells and command posts
A 6058 x 2438 x 2800 mm envelope with PIR sandwich walls and roof, double-glazed PVC windows and PN-HD 60364 electrical. Built on the same line as our ISO Standard shells in Bánovce nad Bebravou.
- External
- 6058 x 2438 x 2800 mm
- Envelope
- PIR sandwich
- Climate
- Electric + A/C
- Fire
- EI 30 / REI 30 opt.
At a glance
- External
- 6058 x 2438 x 2800 mm
- Envelope
- PIR sandwich
- Climate
- Electric + A/C
- Fire
- EI 30 / REI 30 opt.
Overview
Overview
We produce, supply, and customise nearly anything to your specification. The Office and Living family is the broad set of cabins that crews actually live and work in, and within one envelope we supply the full type taxonomy: single and open-plan offices; multi-module and two-storey complexes; accommodation and sleeping units; en-suite living; canteen and kitchen units; meeting units; guard houses; reception and booth units; and changing rooms. Whatever the brief, the same line builds it.
The base unit is a single 20 ft footprint built around an EN 1090-1 EXC2 steel frame with PIR sandwich panel walls and roof. Each type is reached by changing the internal layout, the window and door positions, and the services package, not by changing the core shell. Office and Living cabins are designed to stack and join: two cabins can be combined laterally by removing a long-wall panel and dressing the join, or vertically into a two-storey block on the same forged corner castings used on our ISO Standard production line. That is how a single office becomes a multi-module complex, an open-plan canteen, or a two-floor staff accommodation block.
Every unit is cut, welded, blasted, painted and fitted out in our hall in Bánovce nad Bebravou. The welding line runs under EN ISO 3834-2 production-level qualification, which feeds the EN 1090-1 EXC2 chain. The fit-out cell handles the electrical, HVAC, plumbing rough-in and internal cladding before the unit leaves the building.



Build standard
Construction and materials
Frame
hot-rolled steel, EXC2 to EN 1090-1, welded to EN ISO 3834-2. Eight forged ISO 1CC corner castings per unit for crane lifting, stacking and lashing.
Walls
PIR sandwich panel, typically 80 mm core, steel skin both faces. Thermal conductivity in the 0.022 to 0.023 W/(m·K) band, which gives a typical wall U-value around 0.28 W/(m²·K).
Roof
PIR sandwich panel, typically 100 mm core, sealed perimeter and central drain to corner downpipes. Roof U-value around 0.22 W/(m²·K).
Floor
hot-rolled steel cross members on the base frame, 100 mm mineral wool or PIR core, 22 mm OSB or 19 mm plywood substrate, vinyl or laminate finish on request.
Internal cladding
white melamine-faced board or laminated steel sheet, selectable per face.
Doors
external steel personnel door with multi-point lock, EPDM gasket, drip rail and aluminium threshold. Internal doors are hollow-core to standard interior spec.
Windows
double-glazed PVC frame, tilt-and-turn, integrated roller shutters on request. Bars and laminated glass for high-security variants.
Paint
surface prepared to ISO 8501 Sa 2.5 in our blast booth. Two-coat C3 system to EN ISO 12944. Standard livery RAL 7016 anthracite or RAL 5010 gentian blue. Any RAL code on request.
Specifications
Dimensions and tolerances
Dimensional checks are taken on the FARO Arm Prime 10 in our QA area before paint. The custom envelope band is the range we have produced. Outside that range we run a project review before quoting.
| Standard cabin | Stretched cabin (custom) | |
|---|---|---|
| External length | 6058 mm | 6055 to 7500 mm |
| External width | 2438 mm | 2438 to 2990 mm |
| External height | 2800 mm | 2800 to 3000 mm |
| Internal clear height | approx. 2500 mm | up to 2700 mm |
| Door opening (single leaf) | 875 x 2000 mm | per layout |
| Window aperture (typical) | 900 x 1200 mm | per layout |
| Empty mass (typical) | 2500 to 2900 kg | per build |
| Crane lift points | 4 forged ISO 1CC corners | 4 forged ISO 1CC corners |
| Stack rating | up to two storeys, four high transport stack | as engineered |
Certified
Certifications and norms
- EN 1090-1 EXC2 (execution class for steel structures)
- EN ISO 3834-2 (welding, production-level qualification)
- ISO 9001 (quality management)
- ISO 14001 (environmental management)
- ISO 8501 Sa 2.5 (surface preparation)
- EN ISO 12944 C3 (anti-corrosion coating)
- PN-HD 60364 (low-voltage electrical installation)
- AQAP 2110:2017 (NATO quality assurance, available on defence builds)
- EN 13501-1 reaction-to-fire classification for the panel system on request
- EI 30 fire-rated variant available on request, with the panel assembly tested and certified for the full build, not the foam alone
Deployment
Typical use cases
The same envelope serves the full type range. Typical configurations include:
Single and open-plan offices
Site office on a construction or infrastructure project: single cabin with two desks, a small meeting table, electric panel heater, two double sockets per long wall, LED ceiling lighting. Joined laterally with a sanitary cabin from our Sanitary and Septic family when crew size grows. Meeting units follow the same office fit-out.
Configure
Customisation options
single open-plan, partitioned office and meeting, two-bed cell, four-bed cell, command console, kitchenette plus dining, dressing room plus locker. Sanitary cells with WC, shower or laundry are built in the Sanitary and Septic family and joined to this body if a single envelope is needed.
Lead time
Lead time and delivery
Catalog cabin (Office and Living, no structural changes)
6 to 10 weeks
6 to 10 weeks from order to ex works.
Custom cabin (layout, fire rating, defence spec, stacked block)
10 to 16 weeks
10 to 16 weeks from order to ex works.
Framework call-off
as agreed in the framework contract. A multi-year government defense framework runs on locked pricing and held lead times across call-offs.
Default delivery is EXW Bánovce nad Bebravou
DAP and DDP are available on request. CMR, manuals in the buyer's language and as-built documentation are handed over with the unit.
Proven in service
Reference deployments
Two-floor staff accommodation for a Czech hospitality and leisure client
- Client
- Czech Republic
- Year
- 2024
Tanax supplied wide-body accommodation cells, stacked on two floors, built to REI 30, EXC2 and a C3 paint stack for the alpine mountain climate of the Czech Republic.
View project →Leisure-season containers for a Slovak hospitality and resort operator
- Client
- Slovak Republic
- Year
- 2023 / 2024
Mineral-wool insulated 6055 × 2435 mm hulls supplied to a Slovak resort group for leisure-season service. Built for outdoor duty across opposite climates, from a high-traffic summer site to an exposed mountain station, under one operator.
View project →Training modules for the Slovak Police, designed and assembled on site
- Client
- Slovak government
- Year
- 2024-2025
Architectural design, delivery, assembly, electrical fit, HVAC and camera prep. Co-financed under an EU funding instrument for internal security.
View project →FAQ
FAQ
Send a specification. Get a fixed quote.
Engineering review included. Quotation turnaround is 3 to 5 working days for standard configurations.