08 / 09

MILITARY COMMAND CONTAINERS

A command post that deploys and sets up fast

Containerized command-post and C2 shelters with workstations, secure communications, climate control and power. EMI shielding and TEMPEST options, hardened, transportable, ready to operate on arrival.

Quality
AQAP 2110
NATO CAGE
4094M
Shielding
EMI / TEMPEST opt.
Steel
EN 1090 EXC2

At a glance

Quality
AQAP 2110
NATO CAGE
4094M
Shielding
EMI / TEMPEST opt.
Steel
EN 1090 EXC2

Overview

Overview

We design, build and customise military command containers to your specification. A command container is a deployable, hardened shelter that turns a prepared site into a working command post: integrated workstations, communications fit-out, climate control, power and the structural protection a forward role requires. The shelter is engineered, built and fitted out on our line, so it arrives transportable, weatherproof and ready to operate rather than as a shell to be kitted out in the field.

This is the full range a command and control buyer needs, customised to the brief: single-cell command posts, multi-cell command nodes joined into one operations room, communications and equipment shelters, and rapid-deploy variants sized for movement by truck, rail, sea or air. Command-post work runs through our custom and special-purpose track, the same EN 1090-1 EXC2 line and AQAP 2110 documentation discipline behind our government defense supply, and is handled under our Slovak Defense Trade License with secure handover.

The advantages are readiness and protection. The shelter is built indoors against a fixed specification, EMI shielding and TEMPEST measures are engineered into the build rather than retrofitted, and the unit is sized from the outset for the transport mode and the threat environment it will face.

Government defense unit
Defense programme delivery
Command-post fit-out interior

Build standard

Construction and materials

A command container is built on a hardened version of our special-purpose and custom envelopes, then fitted out for operations. Common build elements:

01

Envelope

EN 1090-1 EXC2 steel frame and body, hot-dip galvanised substructure on request, ISO 1CC corner castings for transport and handling.

02

Protection

reinforced wall and roof build-up, fire-rated detailing to EI 30 or REI 30 on request, blast and fragment provisions where the role requires.

03

Shielding

EMI shielding and TEMPEST measures, shielded entry panels, filtered penetrations and bonded earth, engineered into the build.

04

Fit-out

command-post desks and workstations, map and display walls, cable trays and conduit, equipment and communications racks, blackout and light-discipline detailing.

05

Climate and power

heating and air conditioning sized to the occupied load, CEE inlets, generator-ready inlets, automatic transfer switching, IP-rated fittings and RCD protection.

06

Access and security

hardened door sets, access control, intrusion detection and camera preparation, no vision panels where the role demands.

07

Mobility

lifting and lashing points proof-loaded to spec, skid or trailer sub-assemblies, configured for road, rail, sea or air movement.

08

Finish

ISO 8501 Sa 2.5 surface preparation, two- or three-tone livery, low-visibility coatings on request.

Certified

Certifications and norms

The execution class and the defense-quality chain are the headline. Run on the same line:

  • EN 1090-1 EXC2 (execution class for the steel structure)
  • EN ISO 3834-2 (welding, production level)
  • EN ISO 9606 welder qualification (MAG 135 and related processes)
  • AQAP 2110:2017 (NATO quality assurance)
  • NSPA NATO CAGE 4094M for defense supply
  • Slovak Defense Trade License and Military Aviation Vendor Approval for cleared programmes
  • ISO 8501 Sa 2.5 surface preparation, EN ISO 12944 corrosion protection
  • EN 10204 3.1 mill certificates on traceable steel
  • ISO 9001 quality and ISO 14001 environmental management

EMI and TEMPEST performance targets and any programme-specific standards are confirmed at the specification stage and engineered into the build under NDA.

Deployment

Typical use cases

01 / 05

Forward command post

A single-cell, rapid-deploy shelter that establishes a working command post on a prepared site, hardened and climate-controlled.

Configure

Customisation options

Anything we can cut, weld, shield, fit out and finish inside the hall can be specified. Common deviation routes:

reinforced build-up, EI 30 or REI 30 fire rating, blast and fragment provisions, hardened door sets.

Lead time

Lead time and delivery

A command container runs on a 10 to 16 week custom schedule from signed-off drawings to ex works dispatch, with shielding and acceptance testing inside that window.

Specification and NDA

within 24 hours of first contact, before sensitive drawings or programme detail leave your side.

Quotation

3 to 10 working

a fixed price and lead time, typically within 3 to 10 working days.

Engineering

shop drawings, shielding design, BOM, weld procedures, customer sign-off gate before steel is cut.

Production and fit-out

envelope, protection, shielding, fit-out and systems built indoors.

Acceptance

shielding, electrical and climate systems tested before dispatch.

Delivery

EXW Bánovce nad Bebravou as default, DAP and DDP on request, with secure handover and the as-built dossier, including export and dual-use checks where they apply.

Proven in service

Reference deployments

The deployments below are described by country and sector only, in line with our anonymised reference policy. Configuration detail is indicative.

All projects

Slovakia, government defense sector

  • Containers supplied under a government defense framework, a subset office-fitted as PIR sandwich command-post variants
  • EN 1090-1 EXC2 steel, hot-dip galvanised undercarriage, double cam-locking end doors, marine plywood floor, RAL exterior livery
  • AQAP 2110, EN ISO 3834-2 welding, NSPA CAGE on the supply chain
  • Use case: command-post and support modules within a national defense framework

This is the genuine adjacency behind the command-container offer: command-post variants delivered through our defense framework supply, on the same line and under the same quality chain.

Central Europe, emergency-management agency

  • Transportable command and coordination shelter for a civil-protection role
  • Climate control, power with generator-ready inlet, workstations and communications fit-out
  • Hardened door set, access control and camera preparation
  • Use case: mobile coordination point deployable to an incident site

The same shelter discipline serves civil crisis response, where a mobile, self-sufficient coordination point is the requirement.

Western Europe, defense training establishment

  • Relocatable command facility for exercises and range control
  • Reinforced envelope, EMI-shielded communications cell, two-tone livery
  • Use case: exercise and training command that redeploys between sites

Training and exercise command rewards a hardened, relocatable facility that sets up quickly and moves with the programme.

FAQ

FAQ

Send a specification. Get a fixed quote.

Engineering review included. Quotation turnaround is 3 to 5 working days for standard configurations.